| Sign In | Join Free | My adobecards.com |
|
Brand Name : ROSEMOUNT
Model Number : 3051CD2A22A1AB4
Place of Origin : Singapore
MOQ : 1 ea
Price : Negotiate
Payment Terms : T/T,PAYONEER
Supply Ability : 20EA
Delivery Time : 6 WEEKS
Packaging Details : In Box
Certification : Does not supply
BRAND : EMERSON ROSEMOUNT
MODEL : 3051CD2A22A1AB4
CATEGORY : Coplanar Pressure Transmitters
SUPPLY : 4-20mA
Measurement type : Differential
Delivery time : 4-6 weeks
3051CD2A22A1AB4 Pressure Transmitters Rosemount 3051C Coplanar Transmitter
Product Information Of : 3051CD2A22A1AB4
| Brand | EMERSON ROSEMOUNT |
| Model | 3051CD2A22A1AB4 |
| SUPPLY | 4–20 mA with digital signal based on HART® Protocol |
| SIZE | Does not supply |
| Weight | 5KG |
Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for differential, gage, and absolute pressure measurement. The coplanar platform enables seamless integration with manifolds, flow, and level solutions.
Capabilities include:
1) The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
2) LOI with straightforward menus and built-in configuration buttons (option code M4).
3) Safety certification (option code QT).
More options:
MR-J3-10A
MR-J3-10B
MR-J3-20A
MR-J3-20B
MR-J3-40A
MR-J3-40B
MR-J3-60A
MR-J3-60B
MR-J3-70A
MR-J3-70B
MR-J3-100A
MR-J3-100B
MR-J3-200A
MR-J3-200B
MR-J3-350A
MR-J3-350B
MR-J3-500A
MR-J3-500B
MR-J3-700A
MR-J3-700B
Rosemount 3051C Pressure Transmitters Information :
| Model | Transmitter type | |||
| 3051C | Coplanar pressure transmitter | |||
| Measurement type | ||||
| D | Differential | ★ | ||
| G | Gage | ★ | ||
| A(1) | Absolute | |||
| Pressure range | ||||
| Differential (Rosemount 3051CD) | Gage (Rosemount 3051CG) | Absolute (Rosemount 3051CA) | ||
| 1 | –25 to 25 inH2O (–62,16 to 62,16 mbar) | –25 to 25 inH2O (–62,16 to 62,16 mbar) | 0 to 30 psia (0 to 2,06 bar) | ★ |
| 2 | –250 to 250 inH2O (–621,60 to 621,60 mbar) | –250 to 250 inH2O (–621,60 to 621,60 mbar) | 0 to 150 psia (0 to 10,34 bar) | ★ |
| 3 | –1000 to 1000 inH2O (–2,48 to 2,48 bar) | –393 to 1000 inH2O (–0,97 to 2,48 bar) | 0 to 800 psia (0 to 55,15 bar) | ★ |
| 4 | –300 to 300 psi (–20,68 to 20,68 bar) | –14.2 to 300 psi (–0,97 to 20,68 bar) | 0 to 4000 psia (0 to 275,79 bar) | ★ |
| 5 | –2000 to 2000 psi (–137,89 to 137,89 bar) | –14.2 to 2000 psi (–0,97 to 137,89 bar) | N/A | ★ |
| 0(2) | –3 to 3 inH2O (-7,46 to 7,46 mbar) | N/A | N/A | |
| Transmitter output | ||||
| A(3) | 4–20 mA with digital signal based on HART® Protocol | ★ | ||
| F | FOUNDATION™ Fieldbus Protocol | ★ | ||
| W(4) | PROFIBUS® PA Protocol | ★ | ||
| X (5) | Wireless (requires wireless options and engineered polymer housing) | ★ | ||
| M(6) | Low-power, 1–5 Vdc with digital signal based on HART Protocol | |||
| Materials of construction | ||||
| Process flange type | Flange material | Drain/vent | ||
| 2 | Coplanar | SST | SST | ★ |
| 3(7) | Coplanar | Cast C-276 | Alloy C-276 | ★ |
| 4 | Coplanar | Alloy 400 | Alloy 400/K-500 | ★ |
| 5 | Coplanar | Plated CS | SST | ★ |
| 7(7) | Coplanar | SST | Alloy C-276 | ★ |
| 8(7) | Coplanar | Plated CS | Alloy C-276 | ★ |
| 0 | Alternate process connection | ★ | ||
| Isolating diaphragm | ||||
| 2(7) | 316L SST | ★ | ||
| 3(7) | Alloy C-276 | ★ | ||
| 4(8) | Alloy 400 | |||
| 5(8) | Tantalum (available on Rosemount 3051CD and CG, ranges 2–5 only; not available on Rosemount 3051CA) | |||
| 6(8) | Gold-plated alloy 400 (use in combination with O-ring option code B) | |||
| 7(8) | Gold-plated 316 SST | |||
| O-ring | ||||
| A | Glass-filled PTFE | ★ | ||
| B | Graphite-filled PTFE | ★ | ||
| Sensor fill fluid | ||||
| 1 | Silicone | ★ | ||
| 2(8) | Inert (differential and gage only) | ★ | ||
| Housing material | Conduit entry size | |||
| A | Aluminum | ½–14 NPT | ★ | |
| B | Aluminum | M20 x 1.5 | ★ | |
| E | Aluminum, ultra low copper | ½–14 NPT | ★ | |
| F | Aluminum, ultra low copper | M20 x 1.5 | ★ | |
| J | SST | ½–14 NPT | ★ | |
| K | SST | M20 x 1.5 | ★ | |
| P(9) | Engineered polymer | No conduit entries | ★ | |
| D(10) | Aluminum | G½ | ||
| M(10) | SST | G½ | |
| Wireless options(11) | |||
| Wireless transmit rate, operating frequency, and protocol | |||
| WA3 | User Configurable Transmit Rate, 2.4 GHz WirelessHART | ★ | |
| Antenna and SmartPower™ | |||
| WP5 | Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately) | ★ | |
| Options | |||
| Extended product warranty | |||
| WR3 | 3-year limited warranty | ★ | |
| WR5 | 5-year limited warranty | ★ | |
| Plantweb™ control functionality | |||
| A01 | FOUNDATION Fieldbus control function block suite | ★ | |
| Plantweb diagnostic functionality | |||
| DA0 | Loop Integrity HART Diagnostic | ★ | |
| D01 | FOUNDATION Fieldbus Diagnostics Suite | ★ | |
| Alternate flange(12) | |||
| H2 | Traditional flange, 316 SST, SST drain/vent | ★ | |
| H3(7) | Traditional flange, alloy C, alloy C-276 drain/vent | ★ | |
| H4 | Traditional flange, cast alloy 400, alloy 400/K-500 drain/vent | ★ | |
| H7(7) | Traditional flange, 316 SST, alloy C-276 drain/vent | ★ | |
| HJ | DIN-compliant traditional flange, SST, 7/16-in. (10 mm) adapter/manifold bolting | ★ | |
| FA | Level flange, SST, 2-in. (51 mm), ANSI class 150, vertical mount 316 SST drain/vent | ★ | |
| FB | Level flange, SST, 2-in. (51 mm), ANSI Class 300, vertical mount 316 SST drain/vent | ★ | |
| FC | Level flange, SST, 3-in. (76 mm), ANSI Class 150, vertical mount 316 SST drain/vent | ★ | |
| FD | Level flange, SST, 3-in. (76 mm), ANSI Class 300, vertical mount 316 SST drain/vent | ★ | |
| FP | DIN level flange, SST, DN 50, PN 40, vertical mount 316 SST drain/vent | ★ | |
| FQ | DIN level flange, SST, DN 80, PN 40, vertical mount 316 SST drain/vent | ★ | |
| HK(13) | DIN compliant traditional flange, SST, .4 in. (10 mm) adapter/manifold bolting 316 SST | ||
| HL | DIN compliant traditional flange, SST, .5 in. (12 mm) adapter/manifold bolting 316 SST | ||
| Manifold assembly(14) | |||
| S5 | Assemble to Rosemount 305 Integral Manifold | ★ | |
| S6 | Assemble to Rosemount 304 Manifold or Connection System | ★ | |
| Integral mount primary element(13)(14) | |||
| S3 | Assemble to Rosemount 405 Compact Orifice Plate | ★ | |
| S4(15) | Assemble to Rosemount Annubar™ or Rosemount 1195 Integral Orifice | ★ | |
| Seal assemblies(14) | ||
| S1(16) | Assemble to one Rosemount 1199 seal | ★ |
| S2(17) | Assemble to two Rosemount 1199 seals | ★ |
| Mounting bracket(18) | ||
| B4 | Coplanar flange bracket, all SST, 2-in. pipe and panel | ★ |
| B1 | Traditional flange bracket, CS, 2-in. pipe | ★ |
| B2 | Traditional flange bracket, CS, panel | ★ |
| B3 | Traditional flange flat bracket, CS, 2-in. (51 mm) pipe | ★ |
| B7 | Traditional flange bracket, B1 with SST bolts | ★ |
| B8 | Traditional flange bracket, B2 with SST bolts | ★ |
| B9 | Traditional flange bracket, B3 with SST bolts | ★ |
| BA | Traditional flange bracket, B1, all SST | ★ |
| BC | Traditional flange bracket, B3, all SST | ★ |
| Product certifications | ||
| E8 | ATEX Flameproof and Dust Certification | ★ |
| I1(19) | ATEX Intrinsic Safety and Dust | ★ |
| IA | ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only | ★ |
| N1 | ATEX Type n Certification and Dust | ★ |
| K8 | ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1) | ★ |
| E4(20) | TIIS Flame-proof | ★ |
| E5 | FM Explosion-proof, Dust Ignition-Proof | ★ |
| I5(21) | FM Intrinsically Safe, Nonincendive | ★ |
| IE | FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only | ★ |
| K5 | FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2 | ★ |
| C6 | CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 | ★ |
| E6 | CSA Explosion-proof, Dust Ignition-proof, Division 2 | ★ |
| I6(9) | CSA Intrinsic Safety | ★ |
| K6 | CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) | ★ |
| E7 | IECEx Flameproof, Dust Ignition-proof | ★ |
| I7 | IECEx Intrinsic Safety | ★ |
| N7 | IECEx Type n Certification | ★ |
| K7 | IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7) | ★ |
| E2 | INMETRO Flameproof | ★ |
| I2 | INMETRO Intrinsic Safety | ★ |
| IB | INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
| K2 | INMETRO Flameproof, Intrinsic Safety | ★ |
Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.
If needed, please contact us for specific prices.
OUR MAIN BRAND:

|
|
3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box Images |